Three-phase Hybrid Inverter
Product Features:
Flexible configuration:
Support PV, diesel generator, battery, load at the same time access, also has strong adaptability, support black start
Compatible with lead acid and lithium batteries and other battery type
Various working modes can be set flexibly
Safe and reliable:
Passed IEC/EN 62109-1/-2, IEC/EN 62477-1, IEC/EN 61000-6-1/-6-3, European grid connection: EN50549-1, German grid connection: VDE4105/0124 , UK grid connection: G99, South Africa: NRS097-2-1:2017 test certification
Battery reverse connection protection, anti-power control function;
Advanced:
Home smart energy management system of PV Hybrid Inverter
Support full power discharge, automatic management of battery charge and discharge
Equipped with CAN port, RS485 port, RS232 port for remote control, DRM port, which makes the system smart and flexible
Abundant configuration:
It is more economical to support multiple operating modes Can be as a UPS for the important loads when power off.
|
Benefits |
Application |
● Higher yields, reduce electricity costs by 50% per year
● Free energy available at night
● Participate in peak load shifting to gain additional economic benefits
● keeping critical load operation in power off
● Support 7*24 remote service |
● Solar Villa
● Telecom Base Station
● Solar Plus Storage
● Solar Farm
● Residential Rooftop
● Field Power Supply |
Model | SI3P8KHE | SI3P10KHE | SI3P12KHE | SI3P15KHE |
Input(PV) | ||||
Max.input power(kW) | 12KW | 15KW | 18KW | 22.5KW |
Max. DC voltage(V) | 1000V | |||
MPPT voltage range(V) | 180-850V | |||
Max.input current of single MPPT(A) | 13A | |||
MPPT tracker/strings | 2/1 | 2/2 | ||
AC output | ||||
Rated output power(KVA) | 8KVA | 10KVA | 12KVA | 15KVA |
Max. output current(A) | 12.7A | 15.9A | 19.1A | 23.8A |
Grid voltage/range(V) | 400V/360V~440V | |||
Frequency (HZ) | 50/60Hz | |||
PF | 0.8lagging-0.8leading | |||
THDI | <3% | |||
Type of grid connection | 3W+N+PE | |||
Battery | ||||
Battery voltage range(V) | 125V~600V | |||
Max. charging voltage(V) | 600V | |||
Full battery voltage(V) | 210V | 270V | 300V | 375V |
Rated charge/discharge current(A) | 50A | |||
Battery type | Lithium /Lead-acid | |||
Communication interface | CAN/RS485 | |||
EPS output | ||||
Rated power (KVA) | 8.8KVA | 11KVA | 13.2KVA | 15KVA |
Rated output voltage(V) | 400V | |||
Rated output current(A) | 12.7A | 15.9A | 19.1A | 23.8A |
Rated frequency (HZ) | 50/60Hz | |||
Automatic switching time (MS) | <20ms | |||
THDU | <2% | |||
Overload capacity | 110%,30S/120%,10S/150%,0.02S | |||
General data | ||||
Battery charge/discharge | 97.50% | 97.50% | 97.60% | 97.80% |
DC Max. efficiency | 97.90% | 98.20% | 98.20% | 98.50% |
Europe efficiency | 97.20% | 97.50% | 97.50% | 97.60% |
MPPT efficiency | 99.90% | 99.90% | 99.90% | 99.90% |
Protection class | IP65 | |||
Noise emission (Typical) | ≤25DB | |||
Operation temperature | ‘-25~+60℃ | |||
Relative humidity | 0~100%(non-condensing) | |||
Altitude | 4000m(>2,000m Derating) | |||
Dimensions W*D*H(MM) | 530*220*560mm | |||
Weight (KG) | 30KG | 30KG | 31KG | 32KG |
Isolation transfomer | No | |||
Self-consumption(W) | <3W | |||
General data | ||||
Display | LCD/APP | |||
Interface:RS485/WiFi/4G/CAN/DRM | Yes/ Opt/ Opt/ Yes/ Yes | |||
Safety standard | IEC/EN62109-1/-2, IEC/EN62477-1 | |||
EMC | IEC/EN 61000-6-1, IEC/EN 61000-6-3 | |||
On-grid | Europe: EN50549-1, Germany:VDE4105/0124, UK:G99,South Africa:NRS097-2-1:2017 |